KBS Coating Australia, Fire Protection System, Cable Spraying, Cable Coating Australia, KBS Coating Installer, Fire Stop System, Painting Contractors, Fireproofing, Penetration Seals, Fireproofing Spray
Showing posts with label KBS Coating. Show all posts
Showing posts with label KBS Coating. Show all posts

Wednesday, November 2, 2011

Fire Detection and Exit Measures at Schools for Fireproofing System

Posted by Fire Protection Coatings on 12:29 AM 0 comments

Every School Management should ensure that there are adequate means to warn people of a fire in the school premises. School Fire Protection could take the form of School KBS Coatings or School Painting Services Australia in larger premises, while in small schools it could be whistles, hand bells, or manually operated fire alarm bell. The key point is to make sure that the fire alarm system can be heard throughout the entire school during an emergency.


A Fireproofing System is of considerable value in providing protection against fire in schools. If not covered promptly, a fire can grow and spread to a level that will be difficult to extinguish. A School Fire Protection system must be monitored throughout the year to enable early detection of a fire even when there is not a single person on the premises or if the fire breaks out in a concealed space.

Smoke and heat detectors should be installed and inspected every six months to make sure that they are working properly. Additionally, batteries in battery operated detectors should be exchanged at least once a year. Moreover, Adequate fire alarm call points should be installed all around the school.

The common causes of fire in schools can be malicious fire, External waste mismanagement, inadequate control of building contractors, Poor housekeeping or storage arrangement and Electrical fires.

Let us see, what can be the means of escape in case of a fire break out in schools?

(a) School Authorities should make sure that there are an adequate number of exits from school buildings and places of assembly. However the number of exits required for a given building or assembly place depends on the maximum number of people that can occupy a space or the capacity of each exit as well as the travel distance required. You can consult with your local Fire Officer so as to know the number of exits required in your particular building.

(b) Fire escape routes in the premises must be clearly marked and all fire escape signs should be stick in places that clearly indicate escape routes.

(c) Keep exit doors unlocked whenever the building or space is occupied. You can use push bars where School Maintenance or security concerns require doors to be locked from the outside.


These means of escape from fire can help you to protect children and other staff members of school during fire. But having School KBS Coatings or School Painting Services Australia can keep you away from fire altogether. Precaution is always considered better than cure. Hence School buildings must be adequately fire protected with painting or coatings. Children are our future and their education directly relates to our growth. Ensuring School Fire Protection is key to it.

Robertson Coatings is a Dulux accredited company specialized in Painting and Maintenance programs with Interior Fireproofing for Schools, Commercial Buildings, Large Domestic, Large Industrial, Maintenance Programs. It is a Australian certified applicator for interior fireproofing and KBS Coating and KBS Fire-stopping system.

Continue...


Thursday, January 20, 2011

Penetration Seals – Features and Design Contemplations

Posted by Fire Protection Coatings on 8:50 PM 1 comments


Nowadays, Penetration Seals are widely adaptable fireproofing system. So, here we will discuss about features and design consideration of cable penetration seals



We all are familiar with that fire resist compartments are made to include fire as well as smoke from scattering within building structures. Yet, the rule of compartmentation can also at hand a equivalent menace as most cloaked craters among fire resisting walls as well as floors are interlinked. The magnitude of cable penetration seals gap in this sort of construction so essential to ensure the compartmentation systems work to their utmost aptitude to keep life as well as property.

Features of Penetration Seals:

 - Non-shrink fire rated mortar to pipes as well as Cable Penetration.
 - Intumescent and mineral wool installed around pipes and cables.
 - Intumescent collars, wraps and pastes for all plastic pipes or conduits passing through large slab or wall  penetrations.
 - Fire rate calcium vermiculite, silicate and rockwool boards for wall as well as floor penetrations.
 - Flexible fire rated foams around pipes where expansion and contraction is important. This is usually part of a fire mortar system.
 - Mastic seals, acrylic or polyurethane, around cables and pipes.

More often than not, these fire as well as blast rated flexible seal available in variety of products for numerous relevancies. Additional, seal closes the pipe penetration and lets flexible movement to the pipe in operation duration. The seal comes in range of diverse sizes, fire classes and shapes. Moreover, it is easy to install on partition & decks, single & double sided on exposed and unexposed side.

Cable Penetration Seals
are cost effective and require minimum continuation; however, it can be tailor ended to fit to any size and shape. Moreover, it provides protection against jet fire for up to 2 hours and protection against hydrocarbon fire.

General design contemplations taken for penetration seals: While penetrations can take place in assorted building elements, there are a numeral of significant norms which oblige consideration in seminal the apt kind of sealing system to be used.

- Performance criteria
- Horizontal/vertical orientation
- Fire resistance period
- Insulation requirement
- Wall/floor/linear gap
- Movement or Vibration
- Thermal expansion
- Mechanical strength
- Loadbearing

If we take look in today’s rising technology world then there are many manufacturers who are involved to offer standardized Penetration Seals, Cable Spraying, Cable Coating, etc.

Robertson Coatings has been established in 2004. It is a diversified company specialized in offer Commercial, Cable Coating Australia, KBS Coating, Mastic Paint, Intumescent Coating, Interior Fireproofing Paint, Painting Contractors, Cable Penetration Seals and many more. For more information about services as well as diverse products please do visit: http://www.robertsoncoatings.com.au

Continue...


Wednesday, December 29, 2010

Coating Industry - Robertson Coatings Pty Ltd Obtained License of the Quality Management System

Posted by Fire Protection Coatings on 8:20 PM 1 comments

Robertson Coatings Pty Ltd - a Dulux accredited company announced license of the quality management. It offers numerous featured services with inclusion of ISO 9001/2008 Certification which ensures that you are dealing with a company, meets the highest standards of quality as well as safety.


Robertson Coatings – a coating industry has been got the hold of license for the quality management system. This registration covers the Quality Management System for the provision of Commercial Painting and Maintenance Services, including Fire Protection Coating and School Maintenance.

This Coating Industry offers Painting and maintenance programs for Schools, Commercial Buildings, Large Domestic and Large Industrial. In addition, Robertson Coatings is fully recognized contractors as well as dedicated to provide state-of-the-art Cafco SPRAYFILM® WB3, Passive Fire Protection Coatings and more.

Now, after this license all fire rated painting systems of site comes with Licensed Prompt Installer, Licenced International 212 Fire Coatings Installer, Commercial Industrial Fire Protection works, Licensed KBS Installer and Structural Steel Applications.

At Robertson Coatings Pty Ltd, one will be avail with professional onsite assessments to ensure that all necessary work is done on time and on budget. Further, we also offer detailed quotes and lump sum quotations that meet budgets as well as maintenance targets.

KBS Coating of Robertson Coatings has been successfully tested for different standards like DIN 4102, IEC 332-3, BS 476, FM3971 and ASTM 2863. Furthermore, our all Passive Fire Protection products as well as systems have been tested to an equivalent or more severe: UL 1479, FM Global 3971, AS4072.1.

For all your Fireproofing, Fire Stop Systems, KBS Coating, Painting Contractors and Cable Spraying Requirements, please Contact Robertson Coatings Pty Ltd or Visit Here: http://www.robertsoncoatings.com.au



Robertson Coatings has been established in 2004. It is a diversified company specialized in offer Cable Coating Australia, Commercial, Industrial Painting, KBS Coating, Cable Penetration Seals, Mastic Paint, Intumescent Coating, Commercial Re-Painting, Maintenance Painting and many more. Robertson Coatings provides services in all areas of Australia as well as maintains a 100% safety record, with zero accidents, injuries or incidents because safety is our number one priority.


Contact Address :  
 
Victorian Office
33 Wangara Road, Cheltenham, 
Victoria 3192

Western Australian Office
19 Dale Street, South Hedland, 
Western Australia 6721 
Telephone: 1300 262 846 
Fax: 1300 002 628




Continue...


Friday, December 10, 2010

Cable Coating Installers in Australia for Fire Stop System

Posted by Fire Protection Coatings on 10:13 PM 0 comments

Today, Fire Stop with KBS Coating is more in demand. It is passive fire protection for cable coating. Here, we will be able to get idea about the scope of application for KBS coating.
Fire Stop System
KBS Coating is one of the passive fire stop system. This passive fire protection from KBS Coating installer is an all around fire safety concept that embraces the passive measures in fire containment design as well as in addition augments the active measures. 

Moreover, this KBS coating Australia is work with a proactive approach taken at the building design stage and intended at addressing an inclusive solution to the fire problem. KBS coating is a water-based fire protective coating that has been invented to provide the fire protection of Fire Stop to group or bundled electrical cables through cable coating. 

The key aspect of KBS Coating is to stop flame circulation along vertical and horizontal cable ways. Furthermore, where circuit veracity based on the remoteness of the cables from fire as well as the incurred temperature that time KBS Coating can delay short circuit. 

Passive Fire Protection
According the insurance companies, engineers and architects fires are no longer a calculable risk. The defeat to a production facility or business due to fire can be fiscally staggering as well as sometimes crippling. Conversely, the majority of these fires are spread through the electrical cable or PVC piping system and KBS Coating is one of the ways to stop these fire accidents. This KBS Coating Australia, Cable Coating Systems do not require power or water to operate in case of fire.





The Scope of Application for Passive Fire Protection is in following Areas:

--  Structural fire protection


--  Compartmentation and containment of fire spread

--  Safe escape routes as well as sage refuge for occupants

--  Life safety of fire service personnel

--   Preserving the function of active fire safety measures. 

If we take a look in to the present situation of passive fire protection market in Australia then it is in developing stage, concentrated on the passive fire protection for load bearing structures (beam and columns) using concrete mostly in the industrial segment.

Nowadays, there are many accredited contractors as well as specialist supplier for offering state-of-the-art Passive Fire Protection Cable Coating that works as a fire retardant or resist fire and its effects. In addition, they also offer Interior Fireproofing, Fireproofing on Steel and many more. So, according to the requirement of your home, school, business place you can utilize the different fire protection services of these fire stop system provider. 


Robertson Coatings has been established in 2004. It is a diversified company specialized in offer Commercial, Industrial Painting, KBS coating Australia, Cable Coating, Fire Stop, Mastic Paint and many more. 
For more information about services as well as diverse products please do visit: http://www.robertsoncoatings.com.au

Continue...


Saturday, November 13, 2010

Fire Protection with KBS Cable Coating

Posted by Fire Protection Coatings on 1:42 AM 1 comments

We know that fire incidents can be occur anytime so usually we always follow basic or pioneer Fire Stop System to cope up with such fire incidents. Today, cable is one of the applicable objects to any kind of business so its Fire Protection is also required. So, here we will discuss about the different ways of Cable Coating Application.

Cables are in pioneer need of this technology world and if we think about the Fire Protection then cables are not exceptions from this. Usually KBS Coating is a water-based fire protective coating which is invented for offering the Fire Protection to group or bundled electrical cables as well as to Penetration Seals.

Moreover, the main function of  KBS Coating is to stop flame circulation along vertical as well as horizontal cable ways. Additionally where circuit integrity depends on the distance of the cables from fire and the incurred temperature that time KBS Coating can delay short circuit.

KBS Coating shields electrical cables via ablation instead of insulation. Further, it is dense as well as thermally conductive in duration of normal cable operating temperatures. There are different ways for applying the KBS Coating so, take a look to these methods.

Surface Preparation
In this cleaning of cables is not required but oil or grease should be removed with dry rags (no solvent). Use of broom or vacuum cleaner is advisable to remove heavy layers of dust.

Spray
This Fire Protection is done in the conventional way by spraying crosswise. In such type of application white of the coating should well cover the color of the cable jacket and the wet thickness of the coating must be at least 2.5 mm on all exposed sides. Normally, the required thickness may be applied in one coat.

Brush:  
Cable Coating through the brushing application requires numerous coats to build up the required thickness. Further, a thin coat applied first and then allowed to dry will aid in building up the required thickness.

Hand:
This Cable Coating tactic is adaptable in large diameter single cables or bundles; however, to achieve a smooth finish use of wet brush is advised. Moreover, thin coat should be allowed to dry before the rest is applied, using both hands like an extrude.

Robertson Coatings has been established in 2004. It is a diversified company specialized in offer commercial, Cable Coating Australia, KBS Coating, Mastic Paint, intumescent coating Interior Fireproofing, maintenance painting and many more.

For more information about services as well as diverse products please do visit: http://www.robertsoncoatings.com.au
Continue...


Monday, September 13, 2010

Cable Coating Installers Australia - KBS Coating installation

Posted by Fire Protection Coatings on 11:23 PM 0 comments


The Fire Stop System also includes the water-based coating in other words weather resistant Cable Coating. In following we are going to confer about the KBS Coating, Cable Penetration Seals with KBS and many more.


Wheatear it is commercial or residential places all require the Fireproofing. However, Fireproofing also must be weather resistant. KBS Coating is one of last out resistant Fire Stop System; it is a water-based ablative Cable Coating that is tough, flexible as well as weather resistant.

As per insurance companies, engineers as well as architects fires are no longer a calculable risk. The loss to a production facility or business because of fire can be financially staggering as well as sometimes crippling. However, the majority of these fires are spread through the electrical cable or PVC piping system and KBS Coating is one of the ways to stop these fire accidents.


KBS Coating stops flame-spread along vertical or horizontal cables as well as extends circuit integrity devoid of affecting the current-carrying capacity. Cable Spraying with KBS Coating must be effectively tested to different standards like DIN 4102, IEC 332-3, FM3971, BS 476 and ASTM 2863.

KBS Sealbags: These are expanding pillows for through-penetration Cable Penetration Seal. These unique fire pillows are ideal Penetration Seals where changes like retrofitting of cables or metal pipes are the rule rather than the exception. These KBS Sealbags must be tested to international standards and have ratings of up to 240 minutes.

KBS Mortar: It is a penetration seal for through-penetration Fire Stop System or saturation seal which offers a non-shrinking, homogenous as well as smoke gastight seal for cables and utility penetrations in walls and floors. They must be tested to international standards and carries ratings from 60 to 240 minutes.

KBS Panel Seal: It is a single or double panel Penetration Seal for through-penetration Fire Stop System. KBS Panel Seal offers smoke gastight as well as Fire-Resistant Seal around penetration utilities like cables, cable trays, pipes and ducts. They require to be tested to international standards and carry ratings of up to 240 minutes.

Today, there are many accredited contractors and specialist supplier for offering state-of-the-art Passive Fire Protection Cable Coating that act as a fire retardant or resist fire and its effects. They also provide Interior Fireproofing, Fireproofing on Steel and many more. So, as per requirement of your home, school, business place you can utilize the different fire protection services of these fire stop system provider.

Robertson Coatings has been established in 2004. It is a diversified company specialized in offer Commercial, Industrial Painting, KBS Coating, Mastic Paint, Fireproofing, Intumescent Coating, Commercial Re-Painting, Maintenance Painting and many more.

For more information about services as well as diverse products please do visit: http://www.robertsoncoatings.com.au
Continue...


Saturday, August 21, 2010

Fireproofing for Steel - Intumescent Coatings

Posted by Fire Protection Coatings on 3:20 AM 2 comments

Fire Protection is the foremost key topic which is faced by both building owners and facility managers. Intumescent Coatings is the passive fire protection method which plays an important role in fire protection.


Fire protection systems are pioneer requirements to the operations of the facility for several reasons. However, the first as well as most important reason is to save lives. Nowadays, many fire protective coatings systems have been invented and out of them “Intumescent Coatings” is passive fire protection method.




What is Intumescent Coating?
It is a passive fire protection specialist paint which chemically reacts in a fire. The coating expands in size to form a char that protects the steelwork for a specified period of time from the heat of the fire.

Intumescent Coating:
The function of passive fire protection as well as protecting structural steel is to offer people inside the building time to leave the building. Steel is a very strong building material but at temperatures of 550C it starts to lose its structural integrity.

To cope up with such condition steel is protection is done through intumescent coating by commonly thick as well as solid coat which finished with a thin protective fire retardant, like a gloss. Such coating is normally applied by airless spray to offer a smooth decorative finish that remains stable at ambient temperatures. Compositions of intumescent coating are based on organic resin binders (Typically acrylated rubber or epoxy).

Passive fire protection - Intumescent coatings offer steel structures with corrosion protection, fire protection (fire stop) and a visual decorative element if required. However, passive fire protection coating is a reactive layer, so it is very important to accomplish the correct thickness of dry film for obtaining the required fire resistance. There are several coats may require to be applied to construct up to a total dry coat thickness to give the required time protection.

In recent years, airless unit for applying intumescent coatings was a pneumatic pump having an air motor and it is capable of providing up to 4 - 5,000 psi at the pump. However, a unit requires a road compressor of about 150 cfm and is a heavy unit.

As technology steps ahead, improvements in passive fire protection intumescent formulation have been reduced the weight of coatings as well as the need for high pressure application. Nowadays, almost all intumescent coatings can be applied with a more compact self contained unit with either a petrol engine or an electric motor.

Today, there are many online sources which offer intumescent coating, cable penetration Seals, Mastic paint, KBS Coating, Fireproofing, Cable Coating and more.
Continue...